bat_mode: fix switch off condition #1574

Merged
merged 1 commit into from
Apr 19, 2024
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 1 addition & 1 deletion packages/control/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -416,7 +416,7 @@ def switch_off_check_threshold(self, chargepoint: Chargepoint) -> bool:
+ charging_ev_data.ev_template.data.nominal_difference)
switch_off_condition = (power_in_use > threshold or
# Wenn der Speicher hochregeln soll, muss auch abgeschaltet werden.
(self.calc_raw_surplus() == 0 and
(self.calc_raw_surplus() <= 0 and
data.data.bat_all_data.data.set.regulate_up and
# Einen nach dem anderen abschalten, bis Ladeleistung des Speichers erreicht ist
# und wieder eingespeist wird.
Expand Down